DEVICE DB | Login |
INDEX | NAME | DIRECTION | REGISTER | COUNT | FUNCTION | TYP | CONVERTION | ENUMS | UNIT |
---|---|---|---|---|---|---|---|---|---|
0 | car_state | READ | 100 | 1 | fc4 | ui16 | 0: charging station defective, 1: charging station ready no car, 2: car charging, 3: waiting for car, 4: charging finnished, car still connected | ||
1 | volt_L1 | READ | 108 | 6 | fc4 | ui32 | V | ||
2 | volt_L2 | READ | 110 | d1 | ui32 | V | |||
3 | volt_L3 | READ | 112 | d1 | ui32 | V | |||
4 | amp_L1 | READ | 114 | 6 | fc4 | ui32 | x/10 | A | |
5 | amp_L2 | READ | 116 | d4 | ui32 | x/10 | A | ||
6 | amp_L3 | READ | 118 | d4 | ui32 | x/10 | A | ||
7 | power_total | READ | 120 | 2 | fc4 | ui32 | x/100 | kW | |
8 | energy_total | READ | 128 | 2 | fc4 | ui32 | x/10 | kWh | |
9 | energy_charge | READ | 132 | 2 | fc4 | ui32 | x/360000 | kWh | |
10 | volt_N | READ | 144 | 2 | fc4 | ui32 | V | ||
11 | power_L1 | READ | 146 | 6 | fc4 | ui32 | x/10 | kW | |
12 | power_L2 | READ | 148 | d11 | ui32 | x/10 | kW | ||
13 | power_L3 | READ | 150 | d11 | ui32 | x/10 | kW | ||
14 | power_factor_L1 | READ | 152 | 8 | fc4 | ui32 | % | ||
15 | power_factor_L2 | READ | 154 | d14 | ui32 | % | |||
16 | power_factor_L3 | READ | 156 | d14 | ui32 | % | |||
17 | power_factor_N | READ | 158 | d14 | ui32 | % | |||
18 | allow | READ & WRITE | 200 | 1 | fc3/fc16 | ui16 | 0/1 | 0: charging not allowed, 1: charging allowed | |
19 | ampere_volatile | READ & WRITE | 299 | 1 | fc3/fc16 | ui16 | A | ||
20 | ampere_eeprom | READ & WRITE | 300 | 1 | fc3/fc16 | ui16 | A |