DEVICE DB Login

General parameter

General Modbus-parameter

Note


Documents

Device Description File



Profile

INDEX NAME DIRECTION REGISTER COUNT FUNCTION TYP CONVERTION ENUMS UNIT
0 car_state READ 100 1 fc4 ui16 0: charging station defective, 1: charging station ready no car, 2: car charging, 3: waiting for car, 4: charging finnished, car still connected
1 volt_L1 READ 108 6 fc4 ui32 V
2 volt_L2 READ 110 d1 ui32 V
3 volt_L3 READ 112 d1 ui32 V
4 amp_L1 READ 114 6 fc4 ui32 x/10 A
5 amp_L2 READ 116 d4 ui32 x/10 A
6 amp_L3 READ 118 d4 ui32 x/10 A
7 power_total READ 120 2 fc4 ui32 x/100 kW
8 energy_total READ 128 2 fc4 ui32 x/10 kWh
9 energy_charge READ 132 2 fc4 ui32 x/360000 kWh
10 volt_N READ 144 2 fc4 ui32 V
11 power_L1 READ 146 6 fc4 ui32 x/10 kW
12 power_L2 READ 148 d11 ui32 x/10 kW
13 power_L3 READ 150 d11 ui32 x/10 kW
14 power_factor_L1 READ 152 8 fc4 ui32 %
15 power_factor_L2 READ 154 d14 ui32 %
16 power_factor_L3 READ 156 d14 ui32 %
17 power_factor_N READ 158 d14 ui32 %
18 allow READ & WRITE 200 1 fc3/fc16 ui16 0/1 0: charging not allowed, 1: charging allowed
19 ampere_volatile READ & WRITE 299 1 fc3/fc16 ui16 A
20 ampere_eeprom READ & WRITE 300 1 fc3/fc16 ui16 A