DEVICE DB
Login
General parameter
Devicename:
Manufacturer:
myGEKKO
Belimo
Carlo Gavazzi
EMU
Hager
Senzomatic
SunGrow
Goodwe
Huawei
Heidelberg Amperified
SMA
Dimplex
Daikin
Schneider Electric
Meltem
ABB
Mennekes
RCT Power
Kostal
Growatt
Fronius
SolarEdge
ÖkoFEN
Stiebel Eltron
Viessmann
Spelsberg
ProMinent
Fujitsu
Hidros
ABL
Pracht
MTF Samsung
Sofar Solar
Azzurro
Micropelt
MClimate
Dragino
Milesight
Netvox
Elsys
tabs
IM Buildings
Enerthing
Shelly
Rinck Electronic
Siemens
Buderus
Vaillant
WBC Wallbox
Keba
SolaX Power
Sontex
Mitsubishi Electric
Thermokon
Heliotherm
Victron Energy
go-e
Atess Power
RAKwireless
Deye
BMW i.
E3DC
Elsner
Hoval
2N
amazon alexa
BOSE
BRINK
DoorBird
ekey
Eltako
Kampmann
my-PV
OPUS
Philips Hue
Phoenix Contact
IKEA
PLUGGIT
PROXON
RTI
SONOS
Tecalor
Telenot
Thies
Varta
Waldmann
westaflex
Seneca
Kopp
IDM
Clivet
Xiaomi
Bosch
Enphase
Sinexcel
ZJBENYI
Megarevo
Chisage ESS
Sunket ESS
Carpemar
Wachendorff
DZG
Webasto
Panasonic SANYO
LG
Alfen
Chint
Schrack
Frauenhofer ISE
Type:
Current meter
PV-Inverter
Flow meter
Wallbox
Heat pump
Sensor
Pellet heating
Pool control
Ventilation unit
Radiator valve
Room Thermostat
Button
Socket/Power outlet
Dimmer
Lamp
Air conditioner
Blind
Gas Heater
Alarm
Access
Energy meter
Alarmsystem
Control circuit
Stoves
Intercom
Multifunctional
Switch relay
Field tester
Outdoor station
Voice assistant
Sound processor
Heat recovery unit
Audio distribution
Modem
Speaker
Weather station
Controller
Gateway
Heat cost allocator
Automation Control System
Room controller
Switch
Heating rod
Battery-Inverter
Hybrid-Inverter
Portal
Protocoll:
NOT DEFINED
MODBUS TCP
MODBUS ASCII
MODBUS RTU
LORAWAN
MQTT
EEBUS
WEBAPI
OCPP
SERCOM(new)
MODBUS TCP(new)
MODBUS RTU(new)
MODBUS ASCII(new)
REST(new)
SG-READY
NATIVE
Model_nr:
Version_nr:
ID
Min_mygekko_version:
Function_type:
Interface
Air dehumidifier
Progress_state:
no integration
added
pre-check done
profile documented
field test - individual
field test - w/ profile
profile implemented
profile checked
General Modbus-parameter
Timeout:
Min_pause:
Wordorder:
Byteorder:
Default_alarming:
Note
from 2024-03-15
Documents
Carpemar IHO Calmeter Registerlist
Carpemar IHO Calmeter Datasheet
Device Description File
Profile
INDEX
NAME
DIRECTION
REGISTER
COUNT
FUNCTION
TYP
CONVERTION
ENUMS
UNIT
0
flow
READ
0
2
fc4
int32
x/10
l/h
1
temp_internal
READ
2
1
fc4
int16
x/100
°C
2
temp_remote
READ
3
1
fc4
int16
x/100
°C
3
temp_difference
READ
4
1
fc4
int16
x/100
°C
4
pressure
READ
5
1
fc4
int16
x/1000
bar
5
power
READ
6
2
fc4
int32
x/100
kW
6
air_bubble_signal
READ
10
1
fc4
ui16
0: no air 1: air detected
7
bubble_detection
READ
11
1
fc4
ui16
0: no air 1: small amount of air 2: medium amount of air 3: high amount of air
8
energy_sum
READ
506
2
fc4
int32
x/100
kWh