DEVICE DB Login

General parameter

General Modbus-parameter

Note


Documents

Device Description File



Profile

INDEX NAME DIRECTION REGISTER COUNT FUNCTION TYP CONVERTION ENUMS UNIT
0 charge_point_power READ 400 1 fc4 ui32 W
1 charge_point_state READ 1000 1 fc4 ui16 "0: ""Available"", 1: ""Preparing"", 2: ""Charging"", 3: ""SuspendedEVSE"", 4: ""SuspendedEV"", 5: ""Finishing"", 6: ""Reserved"", 7: ""Unavailable"", 8: ""Faulted"","
2 cable_state READ 1004 1 fc4 ui16 0: Cable not connected, 1: Cable connected, vehicle not connected, 2: Cable connected, vehicle connected, 3: Cable connected, vehicle connected, cable locked
3 EVSE_fault_code READ 1006 1 fc4 ui32 0: No fault, Other: Fault code
4 current_l1 READ 1008 1 fc4 ui16 mA
5 current_l2 READ 1010 1 fc4 ui16 mA
6 current_l3 READ 1012 1 fc4 ui16 mA
7 voltage_l1 READ 1014 1 fc4 ui16 V
8 voltage_l2 READ 1016 1 fc4 ui16 V
9 voltage_l3 READ 1018 1 fc4 ui16 V
10 active_power_total READ 1020 1 fc4 ui32 W
11 meter_reading READ 1036 1 fc4 ui32 x/10 kWh
12 failsafe_timeout READ & WRITE 2002 1 fc3/fc16 ui16 s
13 charging_current READ & WRITE 5004 1 fc3/fc16 ui16 A
14 alive_register READ & WRITE 6000 1 fc3/fc16 ui16 EMS (Master) writes 1 EVSE (Slave) writes 0 (EVSE checks this register at a period of (Failsafe Timeout)/2 for a value of 1, and sets it to 0. Period cannot go less than 3 seconds)