0 Heidelberg Amperified Energy Control Register layout
0 Heidelberg Amperified Energy Control Register table

Device Description File



Profile

INDEX NAME DIRECTION REGISTER COUNT FUNCTION TYP CONVERTION ENUMS UNIT
0 charging_state READ 5 5 fc4 ui16 1/2/3/4/5/6/7/8/9/10/11 :-/A1 no vehicle plugged, Wallbos doesn't allow charging/A2 no vehicle plugged, Wallbox allows charging/B1 vehicle plugged without charging request, wallbox doesn't allow charging/B2 vehicle plugged without charging request, wallbox allows charging/C1 vehicle plugged with charging request, wallbox doesn't allow charging/C2 vehicle plugged in with charging request, wallbox allows charging/derating/E error/F wallbox locked or not ready/error
1 current_l1 READ d0 ui16 x/10 A
2 current_l2 READ d0 ui16 x/10 A
3 current_l3 READ d0 ui16 x/10 A
4 temperature_(pcb) READ d0 si16 x/10 °C
5 voltage_l1 READ 10 4 fc4 ui16 V
6 voltage_l2 READ d5 ui16 V
7 voltage_l3 READ d5 ui16 V
8 extern_lock_state READ d5 ui16 0/1 system locked/system unlocked
9 power READ 14 3 fc4 ui16 x/1000 kVA
10 energy_since_power_on_high_byte READ d9 ui16 x*2^16 VAh
11 energy_since_power_on_low_byte READ d9 ui16 VAh
12 watchdog_timeout READ & WRITE 257 1 fc3/fc6 ui16 x/1000 s
13 standby_functon_control READ & WRITE 258 1 fc3/fc6 ui16 0/1/2/3/4 enable standby function/-/-/-/disable standby funktion
14 remote_lock READ & WRITE 259 1 fc3/fc6 ui16 0/1 system locked/system unlocked