DEVICE DB Login

General parameter

Note


Documents

Meltem-M-WRG-II-P-E-M-(-F,-FC)-Installations-und-Betriebsanleitung.pdf
Meltem-M-WRG-II-P-E-M-user-manual.pdf

Device Description File

M-WRG-II xx[Meltem]Ventilation unit MODBUS RTU(new) (0x0B00000F00010100).ddf

INDEX ALIAS NAME UNIT
0 TEMPERATURE_SUPPLY_AIR Supply Air Temp C / 10
1 TEMPERATURE_EXTRACT_AIR Extract Air Temp C / 10
2 TEMPERATURE_EXHAUST_AIR Exhaust Air Temp C / 10
3 TEMPERATURE_OUTDOOR_AIR Outdoor Air Temp C / 10
4 HUMIDITY_EXTRACT_AIR Extract Air Humidity % / 327.67
5 CO2_EXTRACT_AIR Extract Air CO2 ppm
6 HUMIDITY_SUPPLY_AIR Supply Air Humidity % / 327.67
8 ERROR_VENT Error Message 0 = OK, 1 = Error
9 FILTER_CHANGE Filter change indicator 0 = not elapsed, 1 = elapsed
10 FROST_PROTECTION Frost Protection 0 = not active, 1 = active
11 EXTRACT_VENT_LEVEL Extract Vent Level m^3/h
12 SUPPLY_VENT_LEVEL Supply Vent Level m^3/h
13 TIME_TO_FILTER_CHANGE Time to Filter Change days
14 OPER_HOURS_VENT_UNIT Vent Unit Oper Hours h
15 OPER_HOURS_FAN_MOTOR Fan Motor Oper Hours h
21 FAN_LEVEL_1 Fan Level 1
22 FAN_LEVEL_2 Fan Level 2
23 FAN_LEVEL_3 Fan Level 3
24 FAN_LEVEL_4 Fan Level 4
180 QUALITY_R41000_12 Quality R41000_12
181 QUALITY_R41016_3 Quality R41016_3
182 QUALITY_R41020_14 Quality R41020_14
200 QUALITY Quality
201 TIMESTAMP Timestamp
202 ERRORNUMBER Errornumber
203 ERRORCOUNTER Errorcounter
204 PAUSE Pause
210 INFO Text