DEVICE DB Login

General parameter

General Modbus-parameter

Note


Documents

0 Abb Terra AC Wallbox Registerlist

Device Description File



Profile

INDEX NAME DIRECTION REGISTER COUNT FUNCTION TYP CONVERTION ENUMS UNIT
0 active_power READ 16412 2 fc4 ui16 x/1000 kW
1 voltage_L1 READ 16406 6 fc4 ui16 x/10 V
2 voltage_L2 READ d1 ui16 x/10 V
3 voltage_L3 READ d1 ui16 x/10 V
4 delivered_energy READ 16414 2 fc4 ui16 Wh
5 charging state READ 16396 2 fc4 ui16 A0-Availability: 0x0000= charging station available, 0x0001= charging station unavailable A1-Charging: Bit7= charging rated current, Bit6~0, 0x00= idle, 0x01= EV plug in pending authorization, 0x02= EV plug in EVSE ready (PWM), 0x03= EV ready for charge S2 closed (no PWM), 0x04= charging contact closed energy delivering, 0x05 other, A2 and A3 reserved for future purpose
6 current_limit READ 16390 2 fc4 ui16 x/1000 A
7 current_L1 READ 16398 6 fc4 ui16 x/1000 A
8 current_L2 READ d7 ui16 x/1000 A
9 current_L3 READ d7 ui16 x/1000 A
10 max_current READ 16400 2 fc4 ui16 x/1000 A