DEVICE DB Login

General parameter

General Modbus-parameter

Note


Documents

Mennekes Compact 2.0s Amtron 11 C2 Registerlist
Mennekes Compact 2.0s Amtron 11 C2 Instruction sheet

Device Description File



Profile

INDEX NAME DIRECTION REGISTER COUNT FUNCTION TYP CONVERTION ENUMS UNIT
0 ev_status READ 256 2 fc4 ui16 0= not initialized, 1= idle, 2= EV connected, 3= preconditions valid but not charging yet ready, 4= ready to charge, 5= charging, 6= error, 7= service mode
1 voltage_L1 READ 1280 4 fc4 float32 V
2 voltage_L2 READ d1 float32 V
3 voltage_L3 READ 1284 4 fc4 float32 V
4 current_L1 READ d3 float32 A
5 current_L2 READ 1288 4 fc4 float32 A
6 current_L3 READ d5 float32 A
7 power_L1 READ 1292 4 fc4 float32 x/1000 kW
8 power_L2 READ d7 float32 x/1000 kW
9 power_L3 READ 1296 4 fc4 float32 x/1000 kW
10 power_overall READ d9 float32 x/1000 kW
11 max_current_session READ 2816 2 fc4 float32 A
12 charged_energy_session READ 2818 2 fc4 float32 kWh
13 charging_current_energy_manager READ & WRITE 770 2 fc3/fc16 float32 A
14 cable_lock READ 781 2 fc4 ui16 0= cable locking unknown, 1= cable unlocked, 2= cable locked, 3= evse with fixed cable
15 charged_energy_total READ 4096 2 fc4 float32 kWh
16 charging_sessions_total READ 4098 2 fc4 ui32
17 solar_charging_mode READ & WRITE 3331 2 fc3/fc16 ui16 0= not active, 1= standard mode, 2= sunshine mode, 3= sunshine+ mode