DEVICE DB Login

General parameter

General Modbus-parameter

Note


Documents

0 Pracht ALPHA MONO XT 1024 Registerlist

Device Description File



Profile

INDEX NAME DIRECTION REGISTER COUNT FUNCTION TYP CONVERTION ENUMS UNIT
0 current_max_total_limit READ & WRITE 40003 2 fc3/fc16 ui16 A
1 current_max_vehicle1 READ & WRITE 40004 2 fc3/fc16 ui16 A
2 current_max_vehicle2 READ & WRITE 40005 2 fc3/fc16 ui16 A
3 appointed_current_vehicle1 READ 30012 2 fc4 ui16 A
4 appointed_current_vehicle2 READ 30013 2 fc4 ui16 A
5 device_temperature READ 30104 2 fc4 ui16 °C
6 release/lock_register_charging READ & WRITE 40103 2 fc3/fc16 ui16 1:release, 2: lock, 255:normal mode, 11: vehicle1 release, 12: vehicle1 lock, 21: vehicle2 release, 22: vehicle2 lock
7 status_vehicle1 READ 30107 2 fc4 ui16 0: no vehicle, 1: vehicle connected, 2: charge request, 3: charge request with fan, 4: bypass
9 set_charging_current_supply READ 30115 2 fc4 ui16 A